List of components
FIGHTER 600P
For the Installer
28
1 Immersion heater 9 kW
2 Hot water sensor
3 Operating thermostat, backup heating
5 Rating plate
6 Temperature limiter
7 Miniature circuit-breaker for the circulation pump,
automatic heating control system, fan and
compressor
8 Switch, positions 0 – 1 –
9 Terminal block, power supply
10 Connector, immersion heater
11 Terminal block, docking
12 Terminal block, compressor
13 Terminal block
14 Terminal block
15 Outside sensor
16 Circulation pump
17 Venting screw
18 Pushbutton, “Extra hot water”
19 Outdoor air damper
20 Connector, fan
21 Connector, reversing valve
22 Terminal block, fan speed
23 Push button Ventilation
24 Blinding plate
26 Motor protection, compressor
27 Compressor
28 Operating capacitor, compressor
29 Relay card with power supply unit
30 Indicator lamp, “Compressor”
31 Indicator lamp, “Defrosting”
32 Indicator lamp, “Immersion heater”
33 High pressure pressostat
34 Microprocessor card
35 Capacity setting, circulation pump
36 Fan
37 Knob, “Heating curve selection”
38 Knob, “Heating curve offset”
39 Pushbutton, “Channel selection”
40 Numerical display with control card behind
41 Low pressure pressostat
42 Pressure gauge, boiler
43 Shuttle valve
44 Shutoff valve, flow radiator circuit
46 Filling/shutoff valve, water heater
47 Safety valve, water heater
48 Expansion valve
49 Filling / drain valve, heating system R20 male
50 Shutoff valve, return line radiator circuit
51 Drain valve, water heater R 20 male.
52 Safety valve, heating system
54 Fan transformer
55 Indicator lamp, “Immersion heater”
56 Indicator lamp “Circulation pump”
57 Start condenser, exhaust air fan
58 Condenser
59 Venting screw
62 Evaporator
63 Air filter (Filter type G2)
65 Drying filter with tank
66 Compressor heater
67 Push button Operating mode
Connection Setting out dimensions
ABC
70 Flow line, radiator circuit .................................................. Compression ring Ø 22 mm 1393 306 ........ 55
71 Return line, radiator circuit ............................................... Compression ring Ø 22 mm 1319 239 .... 548
73 Cold water connection ...................................................... Compression ring Ø 22 mm 1265 252 ...... 405
74 Hot water outlet from water heater ................................... Compression ring Ø 22 mm 1277 295 ...... 300
75 Motor for outdoor air damper
76 Temperature sensor, evaporation
79 Overflow connection, water heater
81 Condensation tray
82 Anode tester
83 Inspection cover with anode
84 Ventilation opening
85 Expansion vessel
87 Temperature sensor, extract air (concealed)
88 Temperature sensor, boiler
89 Temperature sensor, supply line
90 Ventilation connection exhaust air ................................... Ø 125 mm .................... 2109 ...... 374 ...... 420
91 Ventilation connection extract air ..................................... Ø 160 mm .................... 2109 ...... 131 ...... 120
92 Connection, docking, in compression ring Ø 15
93 Connection, docking, out compression ring Ø 15
94 Ventilation connection outdoor air .................................... Ø 125 mm .................... 2109 ...... 154 ...... 420
95 Overflow pipe, safety valve water heater
96 Overflow pipe, safety valve heating
97 Condensation water outlet, fan box
98 Overflow water discharge ................................................. PVC-pipe Ø 32 mm (outside diameter)
99 Collection funnel, waste water