Heating curve offset
With the Heating curve offset button you
can change the offset of the heating
curve and thus the room temperature.
Functions on the front panel
5
For Home Owners
The two lamps next to the operating mode
selector indicate the selected operating mode.
This should not be confused with the indicating
lamps in the numerical display.
Top lamp Supplement
Lit The immersion heater may be con-
nected if necessary, i.e. when the
compressor cannot single handed
cover the heating requirement.
Not lit The immersion heater is disabled.
Flashing The outdoor temperature is higher
than the set blocking temperature for
the immersion heater (however, not
when immersion heater is blocked via
the operating mode selector).
Lower lamp Circulation pump
Lit The circulation pump is operational.
Not lit Circulation pump only operational
during hot water heating.
The top lamp Supplement is lit and the lower
lamp Circulation pump flashes.
Numerical display
In normal mode the boiler temperature is dis-
played here. The two digits on the left indicate
the channel number and the two on the right the
reading/setting of that channel.
In the event of a malfunction, an error message
is displayed alternately with channel number
and value. See Dealing with malfunctions —
Indications on the numerical display.
Extra hot water
Pressing the Extra hot water button
increases the hot water temperature to
approximately 60 °C, providing a rise in
the hot water capacity for approximately 24
hours. The integrated lamp is lit in this mode.
FIGHTER 600P then reverts to normal mode.
Pressing the button once again enables an
ongoing function where the hot water tempera-
ture is increased for 6 hours once a day. The
integrated lamp flashes in this mode,
Pressing the button yet again engages to nor-
mal mode.
D
C
F
Ventilation
Ventilation is increased for 6 hours (party
mode) if the Ventilation button is pressed
in. The integrated lamp flashes in this
operating mode. FIGHTER 600P then reverts to
normal mode.
Pressing the button again reconnects the venti-
lation to normal mode. The integrated lamp
goes out in this operating mode.
NOTE! If FIGHTER 600P is installed in a large
house so that no outdoor air is utilised only
exhaust air, the ventilation will not be increased
in party mode.
E
Operating mode indications
Operating mode
When the heat pump is started, all func-
tions (immersion heater, circulation
pump and automatic heating control sys-
tem) are running. When the operating mode is
changed, the changes are saved in memory so
that the heat pump starts in this chosen operat-
ing mode in the event of a restart, for example,
after a power failure.
Pressing the Operating mode button once dis-
ables the immersion heater.
Pressing it once more stops the circulation
pump as well. However, note that the circulation
pump is operational during hot water heating.
Pressing it yet again reconnects the immersion
heater and the circulation pump.
Channel selection
Use the Channel selection button to
scroll forward through the numerical dis-
play’s channels to see the required read-
ing or setting
Available readings/settings include:
1 Boiler temperature
2 Flow temperature.
3 Outdoor temperature
4 Evaporation temperature
5 Extract air temperature
6 Heating curve
7 Heating curve offset
8 Hot water temperature
9 Blocking temperature, immersion heater
(outdoor temperature)
10 Calculated flow temperature
11 Service mode
12 - 27 Service channels, Note! Only for
professionals
Channel 1 is shown automatically after approxi-
mately 4 hours.
Heating curve selection
Use the Heating curve selection knob to
set the automatic heating control sys-
tem; see under Room temperature.
G
H
I
Functions on the front panel
J
FIGHTER 600P
Time/temperature programme for the drying
process regarding floor heating is operational.
This function is normally only used during
installation