Room temperature
FIGHTER 600P
6
For Home Owners
The indoor temperature depends on several factors.
During the hot season, solar radiation and heat given
off by people and equipment are sufficient to keep the
house warm. When it gets colder outside, the heating
system must be started. The colder its gets, the hotter
the radiators must be.
This adjustment is made automatically, however the
basic settings must first be made on the boiler, see the
section Room temperature - Default setting.
The basic heating is set with the Heating curve selec-
tion knob and with the Heating curve offset knob.
If you do not know the correct settings use the basic
data from the map opposite.
If the required room temperature is not obtained, read-
justment may be necessary.
NOTE! Wait one day between settings so that the tem-
peratures have time to stabilise.
Readjustment the default settings
Cold weather conditions
If the room temperature is low, increase the heating
curve selection setting by one step.
If the room temperature is high, reduce the heating
curve selection setting by one step.
Warm weather conditions
If the room temperature is low, increase the heating
curve offset setting by one step.
If the room temperature is high, reduce the heating
curve offset setting by one step.
Changing the room temperature manually
If you want to temporarily or permanently lower or
raise the indoor temperature relative to the previously
set temperature, turn the
Heating curve offset knob
anticlockwise or clockwise respectively. One scale
marking corresponds to a change of about one degree
in the room temperature.
NOTE! An increase in the room temperature may be
inhibited by the radiator or floor heating thermostats, if
so these must be turned up.
Default setting
Automatic heating control system
Changing the room
temperature
FIGHTER 600P offers the possibility to block immer-
sion heater operations as a function of the outdoor
temperature.
This means that when the outdoor temperature is
above a set value the immersion heater is not con-
nected despite compliance with the normal control
conditions. The set temperature should be selected so
that the heating requirement and the hot water
requirement are lower than the heat pump’s capacity
above this outdoor temperature. This temperature is
dependent on the size of the house, degree of insula-
tion, required room temperature and hot water usage.
Setting this temperature takes place according to the
following:
Scroll to channel 9 using the Channel selection but-
ton. The set value is then shown on the numerical dis-
play. To change the value, press the Ventilation but-
ton (increase the value one step) alternatively the
Extra hot water button (lowers the value one step).
The value can be set between +1 and +25 °C. If this
function is not required select +25 °C, which is also
the setting on delivery.
NOTE! The immersion heater can also be blocked
permanently irrespective of the outdoor temperature
by using the Operating mode button, see the section
Functions on the front panel - Functions on the front
panel.
NOTE! However, when the Extra hot water function is
activated the immersion heater is permitted to be
operational irrespective of the above blocking.
Blocking the immersion heater