Display unit
$
%
&
'
(
)
'LVSOD\
6WDWXV ODPS
2. EXWWRQ
%DFN EXWWRQ
&RQWURO NQRE
6ZLWFK
,1'225 &/,0$7(
0< 6<67(0 ,1)2
+27 :$7(5
990 
Display
Instructions, settings and operational informa-
tion are shown on the display. The easy-to-read
display and menu system, facilitates navigation
between the different menus and options to
set the comfort or obtain the information you
require.
A
Status lamp
The status lamp indicates the status of the in-
door module. It:
lights green during normal operation.
lights yellow in emergency mode.
lights red in the event of a deployed alarm.
B
OK button
The OK button is used to:
confirm selections of sub menus/op-
tions/set values/page in the start guide.
C
Back button
The back button is used to:
go back to the previous menu.
change a setting that has not been con-
firmed.
D
Control knob
The control knob can be turned to the right or
left. You can:
scroll in menus and between options.
increase and decrease the values.
change page in multiple page instructions
(for example help text and service info).
E
Switch (SF1)
The switch assumes three positions:
On ()
Standby ( )
Emergency mode ( )
Emergency mode must only be used in the
event of a fault on the indoor module. In this
mode, the compressor switches off and the
immersion heater engages. The indoor module
display is not illuminated and the status lamp
illuminates yellow.
F
33Chapter 7 | Control - IntroductionNIBE™ VVM 310