TIP
If you wish to set similar scheduling for every
day of the week start by filling in all” and then
changing the desired days.
Caution
If the stop time is earlier in the day than the
start time it means that the period extends
past midnight.
Scheduling always starts on the date that the
start time is set for.
Menu 2.9 - advanced
Menu advanced has orange text and is intended for
the advanced user. This menu has a sub-menu.
Menu 2.9.2 - hot water recirc.
operating time
Setting range: 1 - 60 min
Default value: 60 min
downtime
Setting range: 0 - 60 min
Default value: 0 min
Set the hot water circulation for up to three periods
per day here. During the set periods the hot water cir-
culation pump will run according to the settings above.
"operating time" decide how long the hot water circu-
lation pump must run per operating instance.
"downtime" decide how long the hot water circulation
pump must be stationary between operating instances.