English – 11
English
02. Wait a few seconds until the control unit has completed the device recognition procedure: led L2 switches off. If instead it flashes, it means that
there is some error – see Chapter 10.
03. After adding or removing devices, the automation must be tested again (Par. 6.1).
9.3 - MEMORISING ADDITIONAL TRANSMITTERS
The control unit incorporates a radio receiver for ECCO5 transmitters (various models). The transmitters supplied are not memorised, therefore it is first
necessary to memorise the 1
st
transmitter (Par. 5.6); to memorise additional transmitters, it is possible to choose one of the procedures (Mode 1 or
Mode 2) indicated below. The control unit can memorise a total of 250 units: memorisation in Mode 1 occupies one unit of memory for each transmitter,
while the Mode 2 procedure occupies one unit of memory for each transmitter key.
Before running the memorisation procedures, it is advisable to read them and observe the indicated times.
9.3.1 - Mode 1 memorisation procedure (factory memorisation of the supplied transmitters)
This procedure allows for simultaneously memorising all the transmitter keys, by automatically pairing them to the commands shown in Table 4.
A transmitter memorised in Mode 1 can control only a single automation.
TABLE 4
LED
T5
T2
T4
T3
T1
Fuse 1.6A T
Flash
ECSbus
Stop
Aerial
P4
L4 L3
P3
Keys Paired command
T1 Step-by-step
T2 Partial open
T3 Open only
T4 Close only
T5 Courtesy light: Lit - Off
Memorisation procedure
01. On the control unit (Fig. 27) press and hold button P4 for 3 seconds; when led L4 switches on, release the button.
02. Within 10 seconds from releasing it, press and hold for 3 seconds any button of the transmitter to be memorised.
If the memorisation procedure is successful, led L4 (on the control unit) will flash 3 times.
03. To memorise other transmitters, repeat step 02 within the next 10 seconds otherwise the memorisation phase will terminate automatically.
9.3.2 - Mode 2 memorisation procedure
This procedure allows for memorising one key at a time, by pairing one of the desired commands shown in Table 5.
A transmitter memorised in Mode 2 can control multiple automations (for example: automation 1 controlled by key 1; automation 2 controlled
by key 2; and so forth)
TABLE 5
Memorisation procedure
01. Before proceeding, it is necessary to cancel the memory of
the transmitter to be memorised – see Par. 9.4.
02. In Table 5, choose the command and the number of press-down
actions to be effected on the desired transmitter key.
03. On the control unit (Fig. 28) press and release button P4 for a
number of times corresponding to the chosen command (Table 5);
led L4 must emit a number of fast flashes corresponding to the
chosen command.
04. Within 10 seconds, press and hold for 2 seconds the key of the
transmitter to be memorised: if the memorisation was successful,
led L4 (on the control unit) will flash 3 times.
05. To memorise other transmitters, with the same command, repeat
step 03 within 10 seconds, otherwise the memorisation phase will
terminate automatically.
No. of key
presses
Paired command No. of ashes of led
L4 on the control
unit
once Step-by-step 1
twice Pedestrian opening 2
3 times Open only 3
4 times Close only 4
5 times 230 V light output: On - Off
14
6 times Stop 6
7 times Condominium open 7
8 times High priority open 8
9 times Pedestrian opening 2 9
10 times Pedestrian opening 3 10
11 times Open + lock automation 11
12 times Close + lock automation 12
13 times Lock automation 13
14 times Release automation 14
9.3.3 - Memorisation procedure near the control unit with two transmitters (without using the control unit keys)
With this procedure a NEW transmitter is memorised using a second transmitter (OLD) already memorised and operating, without using the keys of
the control unit but drawing close to the latter.
During the procedure the NEW transmitter is memorised in the same way that the OLD transmitter was memorised (Mode 1 or Mode 2).
• Procedure with OLD transmitter memorised in Mode 1:
01. Draw near the control unit with the two transmitters:
Wait 1 second between one step and the next.
02. On the NEW transmitter press and hold any key for at least 8 seconds then release it.
03. On the OLD transmitter press and hold any key to be copied for at least 2 seconds then release it.
04. On the OLD transmitter press and hold any key to be copied for at least 2 seconds then release it.
05. On the OLD transmitter press and hold any key to be copied for at least 2 seconds then release it.
06.
On the NEW transmitter press and hold a key to be memorised for at least 5 seconds then release it.
Repeat the procedure for each transmitter to be memorised.
• Procedure with OLD transmitter memorised in Mode 2:
01. Draw near the control unit with the two transmitters:
Wait 1 second between one step and the
next.
02. On the NEW transmitter press and hold the key to be memorised for at least 8 seconds then
Fuse 1.6A T
Flash
ECSbus
Stop
Aerial
Fuse 15A
P4
L4 L3 L2
P3
28
27