EasyManua.ls Logo

Nidec COMMANDER S100 - Menu 4: General Settings Details

Nidec COMMANDER S100
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting started
Running the
motor
Drive
parameters
Communications Diagnostics Technical data
UL Listing
Information
80 Commander S100 User Guide
7.3.4 Menu 4 - General
This menu contains parameters related to the general drive settings, communication setup parameters and miscellaneous functions such as defining
parameter values to store when an error occurs.
Figure 7-12 Menu 4 - General
Bit 15
Sequencer
Supply Loss Acon P4.08
No. of Auto-reset a empts
P4.12
Hold drive healthy on
Auto-reset a empts P4.13
Drive reset when Enable or
run applied P4.14
Control Word P4.18
Menu 4 - General
Serial Comms
Run &
Direcon
Indicators
P1.11
Sequencer Input and
Output Indicators
1
0
Menu 6 I/O
Configuraon
Node Address P4.03
Mode P4.04
Baud Rate P4.05
Transmit delay P4.06
Run & Direcon
Indicators P1.12
Bit Funcon
0 Run Forward
1 Run Reverse
2 Run
3 Reverse
4 Jog Forward
5 Jog Reverse
6 Run Permit (Not Stop)
Sequencer Input and
Output Indicators P1.11
Bit Funcon
0 Hardware Enable
1 Soware Enable
2 Forward Limit switch
3 Reverse Limit switch
4 Reference On
5 Reverse Reference
6 Jog Reference
7 UnderVoltage
Error System
Parameter Save 1 selector P4.09
Parameter Save 2 selector P4.10
Parameter Save 3 selector P4.11
Motor Phase Loss detecon P4.15
User Error P4.16
Drive Enable P4.17
Miscellaneous
Load Defaults P4.01
Security PIN P4.02
Save Parameters P4.19
Near Field Communicaon P4.20
Alarm Indicators P1.09
Bit Funcon
0 Motor Overload
1 Drive Overload
2 Autotune acve
3 Limit switch acve
4 Input Phase loss or imbalance
5
4-20mA input loss
6 Current Limit acve
7 Digital output overload
Drive Status Indicators P1.10
Bit Funcon
0 Supply Loss
1 Limit switch acve
2 Thermal Limit acve
3 Current Limit acve
4 Drive Acve
5 Drive Healthy
6 At Speed
7 Zero Speed
Drive
State
Saved
Parameter 1
Saved
Parameter 2
Saved
Parameter 3
Error
Error
History 1
Error
History 2
Error
History 3
Keypad Run/Stop
select P4.07
Up key
Down key
Reset key
P1.12
P1.26
P1.27 P1.28
P1.29P1.30P1.31P1.32
P1.09
P1.10
P1.05
P1.11
Final Enable
P4.01 Restore Factory Defaults
Range: 0 to 2 Default: 0 (None)
Restores the default parameter settings of the drive and will clear any user configured parameter settings.
If this parameter is set to a value other than 0, then the drive will load the appropriate defaults and save parameters. This parameter will be reset
to 0 after the action is completed. If editing on the keypad the action will be performed when the edit is finished by pressing the settings button.
Restoring factory defaults cannot be undone.
If there is an attempt to restore defaults while the drive is running, the defaults will not be restored until the drive stops.
P4.02 Security PIN
Range: 0 to 9999 Default: 0
Defines the 4 digit security pin of the drive. This parameter can be set to a value other than 0 to prevent unauthorized write access to the drive.
When a value greater than 0 has been set, it will not be displayed on the keypad or Marshal app to maintain security. If a value has been set, the
security pin must be entered before any parameter can be adjusted via the keypad or prior to writing parameters to the drive via Marshal.
P4.03 Serial Node Address
Range: 1 to 247 Default: 1
Defines the serial address of the drive.
P4.04 Serial Mode
Range: 0 to 3 Default: 0 (8.2NP)
Defines the serial mode of the drive.
The drive always uses MODBUS RTU and is always a slave. All parameters can be accessed as 16-bit registers.
Value Text Description
0
None No action
1
50 Hz Restore Factory Defaults for 50 Hz region
2
60 Hz Restore Factory Defaults for 60 Hz region
NOTE
Value Serial Mode Description
0
8.2NP 8 data bits, 2 stop bits, no parity bit
1
8.1NP 8 data bits, 1 stop bit, no parity bit
2
8.1EP 8 data bits, 1 stop bit, even parity bit
3
8.1OP 8 data bits, 1 stop bit, odd parity bit

Table of Contents