Safety information Product information Mechanical installation Electrical installation Multi axis system design Technical data
102 Digitax HD M75X Series Installation and Technical Guide
Issue Number: 5
Table 6-6 Open loop and RFC-A maximum permissible continuous output current @ 50 °C (122 °F) ambient
Table 6-7 Open loop and RFC-A maximum permissible continuous output current @ 50 °C (122 °F) ambient with rear duct fitted
Model
Heavy Duty
Maximum permissible continuous output current (A) allowing for 175 % overload for 4.5 s
2 kHz 3 kHz 4 kHz 6 kHz 8 kHz 12 kHz 16 kHz
200 V
01200022 2.2 2.2 2.2 2.2 2.2 2.2 2.2
01200040 4.0 4.0 4.0 4.0 4.0 4.0 4.0
01200065 6.2 6.1 5.9 5.7 5.4 4.9 4.4
02200090 9.0 9.0 9.0 9.0 9.0 9.0 9.0
02200120 11.5 11.3 11.0 10.7 10.3 9.8 9.5
03200160 16.0 16.0 16.0 16.0 15.7 14.0 13.3
400 V
01400015 1.5 1.5 1.5 1.5 1.5 1.5 1.5
01400030 3.0 3.0 3.0 3.0 3.0 2.9 2.5
01400042 3.5 3.4 3.4 3.3 3.2 2.9 2.5
02400060 6.0 6.0 6.0 6.0 6.0 6.0 5.4
02400080 8.0 8.0 8.0 8.0 7.5 6.5 5.4
02400105 9.1 9.0 8.9 8.2 7.5 6.5 5.4
03400135 13.5 13.5 13.5 13.3 12.2 9.9 8.2
03400160 16.0 15.2 14.6 13.3 12.2 9.9 8.2
Model
Heavy Duty
Maximum permissible continuous output current (A) allowing for 175 % overload for 4.5 s with rear duct fitted
2 kHz 3 kHz 4 kHz 6 kHz 8 kHz 12 kHz 16 kHz
200 V
01200022 2.2 2.2 2.2 2.2 2.2 2.2 2.2
01200040 3.8 3.8 3.7 3.5 3.3 3.1 2.7
01200065 3.8 3.8 3.7 3.5 3.3 3.1 2.7
02200090 9.0 9.0 8.9 8.5 8.3 7.9 7.6
02200120 9.2 9.0 8.9 8.5 8.3 7.9 7.6
03200160 14.7 14.6 14.4 14.0 13.1 11.8 11.0
400 V
01400015 1.5 1.5 1.5 1.5 1.5 1.5 1.5
01400030 2.1 2.0 1.9 1.8 1.7 1.7 1.7
01400042 2.1 2.0 1.9 1.8 1.7 1.7 1.7
02400060 6.0 6.0 6.0 6.0 6.0 5.6 4.6
02400080 8.0 8.0 8.0 7.4 6.6 5.6 4.6
02400105 9.2 8.7 8.2 7.4 6.6 5.6 4.6
03400135 12.5 12.3 12.2 11.2 10.2 8.3 6.7
03400160 12.5 12.3 12.2 11.2 10.2 8.3 6.7