Tune the phone completely.
Note: SX-4 smart card is needed.
If the phone resets after certificate restoring, reflash the phone again.
Required equipment and setup:
Phoenix
service software supporting RM-586.
The latest phone model specific
Phoenix
data package.
PK-1 dongle
SX-4 smart card (Enables testing and tuning features)
Activated FPS-10 OR FPS-21 flash prommer OR External smart card reader
Latest flash update package for FPS-10 or FPS-21 flash prommers
CU-4 control unit
USB cable from PC USB Port to CU-4 control unit
PCS-1 cable to power CU-4 from external power supply
XCS-4 modular cable between flash prommer and CU-4
Note: CU-4 must be supplied with +12 V from an external power supply in all steps of certificate
restoring.
Steps
1. Program the phone software.
Note: If the COMBO memory of a phone is replaced, the ENO SW must be flashed first before
performing the "normal" firmware flashing.
2. Execute the certificate restore process in
Phoenix
.
Next actions
After a successful rewrite, you must retune the phone completely by using
Phoenix
tuning functions.
Important: Perform all tunings: RF, BB, and UI.
Energy management calibration
Prerequisites
Energy Management (EM) calibration is performed to calibrate the setting (gain and offset) of AD converters
in several channels (that is, battery voltage, BSI, battery current) to get an accurate AD conversion result.
Hardware setup:
An external power supply is needed.
Supply 12V DC from an external power supply to CU-4 to power up the phone.
The phone must be connected to a CU-4 control unit with a product-specific flash adapter.
Steps
1. Connect CU-4 with MJ-249, and place phone to the Module jig MJ-249.
2. Start
Phoenix
service software.
3. Choose File Scan Product.
4. Choose Tuning Energy Management Calibration.
5. To show the current values in the phone memory, click Read, and check that communication between
the phone and CU-4 works.
RM-497