5 Parameters
BU 0505 EN-3021 139
P511
USS baud rate
(USS baud rate)
S
0 ... 8
{ 3 }
Setting of the transfer rate (transfer speed) via the RS485 interface. All bus participants must
have the same baud rate setting.
SK 54xE and above:
0 =
4,800 Baud
4 =
57,600 Baud
1 =
9,600 Baud
5 =
115,200 Baud
2 =
19,200 Baud
6 =
187,750 Baud
3 =
38,400 Baud
7 =
230,400 Baud
8 =
460,800 Baud
NOTE: For communication via Modbus a transfer rate of maximum 38400 Baud must be
set.
Pos: 316 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P500- P599/Parameter P512 US S-Adresse @ 0\ mod_1328092365912_388. docx @ 11157 @ @ 1
P512
USS address
(USS address)
0 ... 30
{ 0 }
Setting of the FI bus address for USS communication.
Pos: 317 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P500- P599/Parameter P513 Telegr ammausfallzei t [SK 5xxE] @ 0\mod_1328092407709_38 8.docx @ 11180 @ @ 1
P513
Telegram time-out
(Telegram time out)
S
-0.1 / 0.0 /
0.1 ... 1000 s
{ 0.0 }
Monitoring function of the active bus interface. Following receipt of a valid telegram, the
next one
must arrive within the set period. Otherwise the FI reports an error and switches off with the error
message E010 >Bus Time Out<.
0.0 = Off: Monitoring is switched off.
-0.1 = No error: Even if communication between BusBox and FI is interrupted
(e.g. 24V error,
Box removed, etc.), the FI will continue to operate unchanged.
Pos: 319 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P500- P599/Parameter P513 Telegr ammausfallzei t_Ergänzung_01 [SK 1x0E, 2 xxE, SK 5xxE] @ 10\mod_1456911 365722_388.doc x @ 311275 @ @ 1
NOTE:
The process data channels for USS, CAN/CANopen and CANopen Broadcast are
monitoring independently of each other. The decision concerning which channel to
monitor is made by means of the setting in parameters P509 and P510.
For example, in this way it is possible to register the interruption of a CAN Broadcast
communication, although the FI is still communicating with a Master via CAN.
Pos: 320 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P500- P599/Parameter P514 CAN-Baudr ate @ 0\mod_132809246635 0_388.docx @ 11203 @ @ 1
P514
CAN baud rate
(CAN baud rate)
0 ... 7
{ 4 }
Used to set the transfer rate (transfer speed) via the CANbus interface. All bus participants must
have the same baud rate setting. With the use of the CANopen technology unit, settings from this
parameter are only valid if the BAUD rotary coding switch on
the technology unit has been set to
PGM.
0 = 10 kBaud
1 = 20 kBaud
2 = 50 kBaud
3 = 100 kBaud
4 = 125 kBaud
5 = 250 kBaud
6 = 500 kBaud
7 = 1 MBaud *
(for test purposes only)
*) Reliable operation cannot be guaranteed
Information
Data takeover
The baud rate is only read after a Power On, a Reset Node message or a Power On of the
24V bus supply.
Pos: 321 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P500- P599/Parameter P515 CAN-Adre sse @ 0\mod_1328092561242_388.doc x @ 11226 @ @ 1