5 Parameters
BU 0505 EN-3021 161
P741 [-01]
...
[-23]
PZD bus Out
(Process data Bus Out)
S
0000 ... FFFF (hex)
information about the actual
status word and the actual
values that are transferred
via the bus systems.
Standardisation: 8.7
"
Standardisation of setpoint
/ target values"
[-01] = Status word
Status word, source from
P509.
[-02] = Actual value 1 (P543 [-01])
[-03] = Actual value 2 (P543 [-02])
[-04] = Actual value 3 (P543 [-03])
[-05] = Actual value 4 (P543 [-04])
[-06] = Actual value 5 (P543 [-05])
[-07] = res.status OutBit P481
The displayed value depicts
all Bus OUT Bit sources
linked with an "OR".
[-08] = Parameter data Out 1
[-09] = Parameter data Out 2
[-10] = Parameter data Out 3
[-11] = Parameter data Out 4
[-12] = Parameter data Out 5
Data during parameter
transfer.
[-13] = Actual value 1 master function
[-14] = Actual value 2 master function
[-15] = Actual value 3 master function
[-16] = Actual value 4 master function
[-17] = Actual value 5 master function
Actual value of master
function
P502 / P503.
[-18] = PLC status word
Status word via PLC
[-19] = Actual value 1 PLC
[-20] = Actual value 2 PLC
[-21] = Actual value 3 PLC
[-22] = Actual value 4 PLC
[-23] = Actual value 5 PLC
Actual value data via PLC
Pos: 424 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700-P799/Parameter P742 – Datenbank version @ 0\mod_13281780218 21_388.docx @ 13405 @ @ 1
P742
Data base version
(Database version)
S
0 ... 9999 Displays the internal database version of the FI.
Pos: 425 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700- P799/Parameter P743 – Umri chtertyp @ 0\mod_13281780 80214_388.docx @ 13428 @ @ 1
P743
Inverter type
(Inverter type)
0.00 ... 250.00
Displays the inverter power in kW, e.g. "1.50" ⇒ FI with 1.5 kW nominal power.
Pos: 426 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700- P799/Parameter P744 – Ausb austufe @ 0\mod_13281781 35013_388.doc x @ 13451 @ @ 1
P744
Configuration
(Configuration level)
0000 ... FFFF (hex)
This parameter displays the special devices integrated in the FI. Display is in hexadecimal code
(SimpleBox, ControlBox, Bus system).
The display is in plain text when the ParameterBox is used.
SK 500E … 515E = 0000
SK 520E = 0101
SK 530E … 535E = 0201
SK 540E … 545E = 0301
Pos: 427 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700- P799/Parameter P745 – Baugr uppen Version @ 0\mod_1328 178182499_388.doc x @ 13474 @ @ 1
P745
Module version
(Module version)
-3276.8 ... 3276.8 Version status (software version) of the technology unit (SK TU3-
processor is present, i.e. not for SK TU3-CTR.
Have this data available if you have a technical query.
Pos: 428 /Anleitungen/ Elektronik/F U und Starter/5. Parameter/ Parameterauflis tung (P000 ...)/P700- P799/Parameter P746 – Baugr uppen Zustand [SK 5xxE] @ 0\mod _1328178220422_388.doc x @ 13497 @ @ 1