Maintenance
5-3
Nozzle
Cleaning
@
@
@
A
WARNING: Hot!
Risk of burns. Wear
heat-protective clothing,
safety
goggles,
and
heat-protective
gloves.
CAUTION:
Nozzles can be damaged
if
an
open torch, drill,
or
broach is used
for
cleaning.
Use only a
pin-type probe
to
clean
anozzle.
1. Relieve system
pressure
following the instructions
in
your
applicator
product
manual.
WARNING: Even
when
switched
off, Nordson applicators
and
guns
contain electrical
potentials
that can cause
death.
Disconnect and lock
out input
power
to the applicator
main
circuit
breaker.
NOTE: Nordson
Type R fluid is used to clean adhesive
from extrusion
systems. lts advantages
over similar
fluids are that it can be
reused and
that it has an inoffensive
odor.
2.
Disconnect and lock out
input
power
to
the applicator
main circuit
breaker.
4110132
Fig. 5-1
Power Lock Out
O
1995 Nordson CorpoEtion
All
rights
reserved
42-72
lssued
10/95
AsEN-06-[AD-31
EXI-1