Troubleshooting
6-1
Section
6
Troubleshooting
1. lntroduction
WARNING: Allow only
qualified personnelto
perform
the
following tasks. Observe and
follow the safety
instructions in
this document and all other related documentation.
This section
provides
answers to the most
common
problems
that
you
may encounter.
lf
you
cannot solve the
problem
with the answers
in this
section,
contact
your
Nordson representative
for help.
Problem
Possible Cause
Corrective
Action
No adhesive
flows from
gun
module.
Adhesive levellow.
No input
power
Applicator temperature setting too
low.
Hose temperatu re controller setting
too
low
System not at operating temperature
lnsufficient air
pressure
to
piston
pump.
Applicator motor not operational.
Failed heater fuse.
Failed hose
Check level.
Add
adhesive
if needed
Connect
power
to applicator
and
associated
equipment.
Make sure that
i
all circuit
breakers are ON.
Adjust setting
(refer
to applicator
product
manual).
Adjust setting
(refer
to applicator
product
manual).
Verify
READY
light is on and adhesive
or sealant
is melted.
lf not, allow unit to
reach
operating
temperatu
re.
Verify air
pressure
by flushing filter
(refer
to applicator
product
manual).
Verify
motor
operation
(refer
to
applicator
product
manual).
Disconnect and lockout electrical
power
to the applicator.
Check fuse and
replace if
bad
(refer
to applicator
product
manual).
Disconnect and
lockout electrical
power
to the applicator.
Check hose heater
cold
resistance. against
suggested
range
given
in hose
product
manual.
Replace hose if needed
(refer
to hose
product
manual).
A6EN{7-[AD-31EX]-1
@
1995 Nordson Corporation
All ,ights reserued
42-72