Repair
7-37
Removing the
Existing
Handgun
4110132
Fig.7-58
Locking Out lnput Power
CAUTION:
The Nordson handgun, sensor,
and cordset
are not
compatible
with
similar components
of other brands;
therefore,
to
prevent
a
possible
hazard
when replacing an existing
non-Nordson handgun with any
Nordson RTD handgun,
you
will
need to obtain and installa cordset conversion
kit.
See
your
Nordson representative. Possible
hazards include
runaway
temperature and failure to obtain an adequate
ground.
Before removing the existing handgun,
gather
the following:
o
appropriate
protective
clothing
.
3-mm
(1/B-in.)
Phillips screwdriver
o
2o-mm
(s/4-in.)
open-end wrench
o
18-mm
(11/16-in.)
open-end
wrench
1. Make sure that
you
have followed the above
procedure,
Relieving
Hydraulic P ressure, before
proceeding.
WARNING: Risk of electricalshock.
Failure to observe
this
warning
can result in
personal
injury or death.
2. Set the applicator circuit breaker or the disconnect
switch to the
OFF
position.
WARNING:
Even when
switched
off, Nordson applicators
and
guns
contain electrical
potentials
that can cause
death.
Disconnect
and
lock
out
power
to the applicator
main circuit
breaker.
3.
Disconnect and lock out the input
power
line to'the applicator
main
circuit breaker.
@
1995
Nordson Corporalion
All rights reserved
42-72
lssued 10/95
ATEN{8-[AD-31EX]-1