EasyManua.ls Logo

Nordson AD-31 Series - Swivel Bearing Replacement

Nordson AD-31 Series
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-1O
Repair
Swivel Bearing Replacement
1. Relieve
system
pressure
following the instructions in
your
applicator
product
manual.
WARNING: Even when
switched
off, Nordson applicators and
guns
contain electrical
potentials
that can cause death.
Disconnect and lock out input
power
to the applicator
main
circuit breaker.
A
4110132
Fig. 7-13 Power Lock Out
o
ts
@
o
o
I
4203{M8
Fig. 7-14 Disconnecting the
Electrical Switch from the
Hose
(if
applicable)
2. Disconnect
and
lock
out
input
power
to
the
applicator main circuit
breaker.
3. Place the trigger in the locked
position.
lf necessary,
see
Figure 7-2.
4.
lf
your
handgun
has
an
electrical switch, unplug the switch
plug
assembly at the bottom of the trigger handle
from
the
connector on
the hose cordset.
ATEN-08-[AD-31 EX]-l
42-72
lssued 10/95
@
1995 Nordson Corporation
All rights resarved

Table of Contents