Page 286 of 488 Verifying the network
553-3041-210 Standard 4.00 September 2007
7 Exit from LD 135. Enter the command:
****
8 Access LD 117. Enter the command:
LD 117
9 Ping IP addresses on the 100BaseT links.
a. Enter the command:
PING 192.168.0.11
System response:
PING 192.168.0.11 SUCCESSFUL
b. Enter the command:
PING 192.168.0.21
System response:
PING 192.168.0.21 SUCCESSFUL
c. Enter the command:
PING 192.168.0.31
System response:
PING 192.168.0.31 SUCCESSFUL
d. Enter the command:
PING 192.168.0.41
System response:
PING 192.168.0.41 SUCCESSFUL
Note: Replace the sample IP addresses with the IP addresses from your
Planning and Engineering group.
10 Exit from LD 117. Enter the command:
****
End of Procedure