en-938821/2 7 - 9
System Faults
7
!
WARNING
It is advisable to save the parameter table or make a paper printout each time the table is
modified (See Parameter Manual)
The parameter table has not been saved
The message must not be acknowledged:
Cut off the power supply to the system.
Return to the previous system status (reinstall the old memory board).
Restart the system.
Save the parameters (See Parameter manual).
Cut off the power supply to the system.
Re-install the new software version.
Restart the system and continue the procedure.
7.7 A Declared Axis Missing
Message displayed at initialisation
MISSING AXIS
DO YOU WANT TO CONTINUE ? (Y/N)
CONTINUE (Y/N)?
Comment
One of the axes declared in parameter P2 (See Parameter Manual) is missing.
Actions
Acknowledge the message.
Y
The system is available, but power cannot be applied to the machine.
Enter the P2 parameter value corresponding to the axes present
(See Parameter manual).
If required, modify the other axis-related parameters in compliance with
parameter P2.
Reset the system to take the new parameters into account.