en-938821/2 7 - 15
System Faults
7
7.18 Several Axis Drive Sensors Have the Same Address
Message displayed at initialisation
ERROR: SEVERAL AXIS DRIVES SENSORS
POSSESS THE SAME ADDRESS
CONTINUE (Y/N)?
Comment
The same address is set for several axis sensors.
REMARK If several sensors with the same address are connected to the same QVN fibre-
optic bus, the error is not detected.
Actions
Acknowledge the message. ☞
Y
The system is available, but the machining modes are inhibited and power cannot be applied to the system.
The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).
Set different addresses for each of the sensors.
Reset the system to take the new parameter into account.
7.19 List of Drives Different from the List of QVN Axes
Message displayed at initialisation
ERROR: MISMATCH BETWEEN THE DRIVES
PRESENT AND THE QVN AXES DECLARED
CONTINUE (Y/N)?
Comment
The list of drive addresses set does not match the list of speed sensor addresses declared in parameter P71 (See
Parameter Manual).
Actions
Acknowledge the message. ☞
Y
The system is available, but the machining modes are inhibited and power cannot be applied to the system.
The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).
Change the drive address codes.
or
Set correct speed sensor addresses in parameter P71 (See Parameter Manual).
Reset the system to take the new parameter into account.