A - 24 en-938821/2
Parameters Description Value Access by the
or units part programme
E79000 Position reference of the measured 0 à 3599999 Read only
spindle in the group 1/10000 degree
E79001 Group spindle setting 1 / 2
15
of the Read only
maximum speed
E79002 Feed rate potentiometer value 1 / 128 Read only
E79003 Distance remaining to be travelled internal unit Read/write
E79004 Current speed in path internal unit Read only
E79005 Minimum group feed rate potentiometer value % 0 to 255 Read/write
E79006 Minimum group feed rate potentiometer value % 0 to 255 Read/write
E79007 Minimum group feed rate potentiometer value % 0 to 255 Read/write
E79008 Minimum group feed rate potentiometer value % 0 to 255 Read/write
E80000 to E80050 Local data - 99999999 Read/write
to 99999999
E81000 to E81999 Master axis reference positions internal unit Read/write
E82000 to E82999 Slave axis corrections internal unit Read/write
E90000 to E90031 Axis measurement internal unit Read/write
E901000 to E90103 Spindle x position reference 0 to 3599999 Read only
1/10000 degree
E90110 to E90113 Spindle modulo depending on Read only
spindle sensor
E90200 to E90203 Spindle speed setting 1 / 2
15
of the Read only
maximum speed
E90300 to E90303 Maximum spindle indexing speed rev/min Read/write
E90310 to E90313 Spindle indexing in-position window internal unit Read/write
E90320 to E90323 Spindle indexing gain (rev/min)/rev Read/write
E90330 to E90333 Spindle indexing acceleration rev/s
2
Read/write
E90340 to E90343 Threshold at which spindle is considered stopped rpm Read/write
E90350 to E90353 Tolerance interval coefficient 1/256 Read/write
E91000 to E91031 Servo-controlled axis (or spindle) 0 or 1 Read/write
E91100 to E91131 Homing completed or not on the axis (or spindle) 0 or 1 Read/write
E91200 to E91231 AUTO N/M axes (milling) 0 or 1 Read/write
E91300 to E91331 Enable status of clampable axes 0 or 1 Read/write
E92000 to E92031 Enable status of axis origin switches 0 or 1 Read/write
E93000 to E93031 Axis origin switch status 0 or 1 Read only
E93100 to E93131 Measured axis 0 or 1 Read only
E93200 to E93231 Axis declared rotary modulo 360 degrees 0 or 1 Read only