43827101TH Rev.2 124 /
Oki Data CONFIDENTIAL
(1) Transition of menu items
Transition of is selected with [MENU+] or [MENU-] and executed pressing [ENTER].
Transition to is executed with [ENTER] or [BACK].
Select an item with [MENU+] or [MENU-] following the transition.
Pressing [ENTER] executes the test, and pressing [BACK] terminates it.
LEVEL1
xxxxx
xxxxx
[MENU+] [MENU+] [MENU+]
[MENU+] [MENU+] [MENU+]
SWITCH SCAN MOTOR & CLUTCH TEST TEST PRINT REG ADJUST TEST
ENGINE DIAG LEVEL1 [MENU-] [MENU-]
[MENU-] [MENU-]
PAPER ROUTE : PU ID MOTOR [MENU-] PRINT EXECUTE [MENU-] REG ADJ EXECUTE DENS ADJ EXECUTE
TONER SENS BELT MOTOR TEST PATTERN REG ADJ RESULT *2
CVO UP_LU_FU FUSER MOTOR TEST CASSETTE *1 DENS ADJ RESULT *4
REG L/R_OHP_WG REGIST MOTOR PAGE BLT REFLECT RSLT *3 AUTO CALIBRATION
HT THERMISTER T1 HOPPING MOTOR COLOR
HUM_TEMP_DEN FRONT MOTOR DUPLEX *1
<Indication items of color drift correction test result>
Items of *2.
<Indication items of density correction test result>
Items of *4.
BELT_T REGIST SHUTTER MONO SPEED REG ADJ RSLT DENS ADJ RESULT
ID UP/DOWN EXIT SOLENOID COLOR SPEED SNS CARIBRAT (L)
RFID COLOR DUPLEX MOTOR *1: TRAY2 and DUPLEX are displayed only
when these are mounted.
SNS CARIBRAT (R)
F-RL SL BL DT-DC
DUPLEX CLUTCH D-RANGE (L) Y,M,C LEV0 V/D OUT RD
T1 PE_PNE_CVO T2 HOPPING MOTOR D-RANGE (R) Y,M,C H_DUTY DENS-K
T1 CASETTE SIZE T2 FEED CLUTCH CRSE ADJ Y L,R,X H_DUTY DENS-Y
T2 PE_PNE_CVO_CA ID UP/DOWN CRSE ADJ M L,R,X H_DUTY DENS-M
T2 HOP_LF_FED LV FAN TEST CRSE ADJ C L,R,X H_DUTY DENS-C
T2 CASETTE SIZE FUSER FAN TEST FINE ADJ Y L,R,X L_DUTY DENS-K
DUP IN_RA_FNT DUPLEX FAN TEST FINE ADJ M L,R,X L_DUTY DENS-Y
DUP SK_CVO
FINE ADJ C L,R,X L_DUTY DENS-M
REG ADJ Y L,R,X L_DUTY DENS-C
REG ADJ M L,R,X FINAL DENS-K
REG ADJ C L,R,X
FINAL DENS-Y
CRSE ADJ Y [Y-L]
FINAL DENS-M
CRSE ADJ Y [Y-R]
FINAL DENS-C
CRSE ADJ Y [X] DB DENS VALUE
CRSE ADJ M [Y-L]
DELTA-K 01=#***
CRSE ADJ M [Y-R]
DELTA-K 04=#***
CRSE ADJ M [X]
DELTA-K 07=#***
CRSE ADJ C [Y-L]
DELTA-Y 01=#***
CRSE ADJ C [Y-R]
DELTA-Y 04=#***
CRSE ADJ C [X]
DELTA-Y 07=#***
FINE ADJ Y [Y-L]
DELTA-M 01=#***
FINE ADJ Y [Y-L]
DELTA-M 04=#***
FINE ADJ Y [Y-R]
DELTA-M 07=#***
FINE ADJ Y [Y-R]
DELTA-C 01=#***
FINE ADJ Y [X-L]
DELTA-C 04=#***
FINE ADJ Y [X-R]
DELTA-C 07=#***
FINE ADJ M [Y-L]
DENS-K
FINE ADJ M [Y-L]
DENS-Y
FINE ADJ M [Y-R]
DENS-M
FINE ADJ M [Y-R]
DENS-C
FINE ADJ M [X-L]
BEFORE STD=***H
FINE ADJ M [X-R] AFTER STD=***H
FINE ADJ C [Y-L]
FINE ADJ C [Y-L]
FINE ADJ C [Y-R]
FINE ADJ C [Y-R]
FINE ADJ C [X-L]
FINE ADJ C [X-R]
<Indication items of color drift correction belt reflectivity test result> Items of *3.
L-SIDE
R-SIDE
[MENU+]
[MENU+]
[MENU+]
[MENU+]
[MENU+]
CONSUMABLE STATUS PRINTER STATUS FACTORY MODE SET
SENSOR SETTING LED HEAD DATA
[MENU-] [MENU-]
[MENU-] [MENU-]
[MENU-]
K-ID UNIT K-IMPRESSIONS FACTORY MODE *5
TONER SENSOR K
Y-ID UNIT Y-IMPRESSIONS FUSE INTACT *6
BELT UNIT CHECK Y
M-ID UNIT M-IMPRESSIONS
ID UNIT CHECK M
C-ID UNIT C-IMPRESSIONS
<FACTORY MODE setting items. Items of *5
C
FUSER UNIT TOTAL SHEETS CNT FACTORY MODE
REG ADJUST ERROR
TR BELT UNIT FACTORY MODE
Factory work mode
DRUM OVER LIFE
WR POINT REV
<Indication of LED header serial number>
K-TONER (FULL)
SHIPPING MODE
Factory work mode
cleared
n 01 23 45 6789
Y-TONER (FULL)
<FUSE INTACT items> Item of *6
1234567890123
M-TONER (FULL)
FUSE INTACT
n:K,Y,M,C
C-TONER (FULL)
BELT UNIT INTACT: Not cut yet/BLOWN:Cut already
M-WASTE TNR CNT
FUSE UNIT INTACT: Not cut yet/BLOWN:Cut already
C-WASTE TNR CNT
K-ID UNIT INTACT: Not cut yet/BLOWN:Cut already
K-STC MODE CNT
Y-ID UNIT INTACT: Not cut yet/BLOWN:Cut already
Y-STC MODE CNT
M-ID UNIT INTACT: Not cut yet/BLOWN:Cut already
M-STC MODE CNT
C-ID UNIT INTACT: Not cut yet/BLOWN:Cut already
C-STC MODE CNT
K REFILL CNT
Y REFILL CNT
M REFILL CNT
C REFILL CNT
K OVER RIDE CNT
Y OVER RIDE CNT
M OVER RIDE CNT
C OVER RIDE CNT
A
B
B
A
DENS ADJ RAR-SET
DENS ADJ TEST
BOTTOM WRT POINT
BLT REFLECT TEST
LEV0 V/D OUT YMC
LEV0 V/D OUT K
Note: The motor keeps rotating if holding
down the [ENTER] key for two
seco when determining the choice
of the motor. (The motor stops when
the [CANCEL] key is pressed.)
Note: Press and hold down (3 sec) the [ENTER] key to
define a parameter.
Note: Press and hold down (3 sec) the [ENTER]
key to define a parameter.