43827101TH Rev.2 135 /
Oki Data CONFIDENTIAL
BELT=****
FRM[***](xxx)
DB:k**y**m**c**
TR1:k**y**m**c**
TR2:k**y**m**c**
BELT: Constant speed timer value of belt motor (I/O set value) [Unit: HEX]
FRM : [***] = AD value of frame thermistor reading [Unit: HEX]
(xxx) = Frame temperature [Unit: ˚C]
• Pressing the MENU+ key switches over the indication.
DB: Development voltage setup table ID No. [Unit: HEX]
• Pressing the MENU+ key switches over the indication.
TR1: Transfer voltage parameter VTR1 table ID No. [Unit: HEX]
TR2: Transfer voltage parameter VTR2 table ID No. [Unit: HEX]
• Pressing the MENU+ key switches over the indication.
TROFF:**
BELT xxx(***)
TROFF: Transfer OFF voltage setup table ID No. [Unit: HEX]
BELT: *** = Belt temperature [Unit: ˚C]
xxx = AD value of belt thermistor reading [Unit: HEX]
5. Repeat Items 2 to 4, as needed.
6. Press the CANCEL key to terminate the test. (Status of Item 1 restored)
ID=****
• Pressing the MENU+ key switches over the indication.
KID, YID, MID and CID denote the constant-speed timer values of the respective ID motors
(I/O set values) [Unit: HEX].
• Pressing the MENU+ key switches over the indication.