<<DENS ADJ RESULT is executed>>
The same as the key operation of Item 2 in the execution of DENS ADJ EXECUTE.
<<DENS ADJ PAR-SET is executed>>
Indication only, without functionality.
<<AUTO CALIBRATION is executed>>
1 Automatic setting of a density sensor sensitivity correction value is made. ([READY] light
blinking)
2 When the test ends, the test result (OK or error name) appears in the upper line of the
display section, and **** RESULT, in the lower line.
Pressing the [MENU+] key increments the test result sequentially in the display.
Pressing the [MENU-] key decrements the test result sequentially in the display.
Pressing the [BACK] key restores the status of Item 2.
3 Pressing the [CANCEL] key while the test is under way aborts the test ([READY] light comes
on) and restores the status of Item 2.
4. Repeat Item 3, as needed.
5. Press the [BACK] key to terminate the test. (Status of Item 1 restored)
Density correction test items
OK
DENS ADJ RESULT
Display Function
DENS ADJ EXECUTE Execution of Print density adjustment
DENS ADJ PAR-SET Indication is given, without functionality.
DENS ADJ RESULT Viewing of Print density adjustment result
AUTO CALIBRATION Automatic setting of Print density adjustment value