2HA/2HB
1-4-25
(15) Image is partly missing.
(16) Fuser is poor.
(17) Image is out of focus.
(18) Image center does not align with the original center.
Copy example Causes Check procedures/corrective measures
Paper damp. Check the paper storage conditions.
Paper creased. Replace the paper.
Dirty or flawed drum. Clean the drum or, if it is flawed, replace the drum unit (see
page 1-5-23).
Dirty transfer roller. Clean the transfer roller.
Copy example Causes Check procedures/corrective measures
Wrong paper. Check if the paper meets specifications.
Defective pressure springs. Replace the pressure springs.
Flawed press roller. Replace the press roller (see page 1-5-30).
Defective fuser heater. Replace the fuser heater (see page 1-5-31).
Copy example Causes Check procedures/corrective measures
Defective image scanning unit. Replace the image scanning unit (see page 1-5-18).
Drum condensation. Clean the drum.
Copy example Causes Check procedures/corrective measures
Misadjusted center line of image print-
ing.
Readjust the center line of image printing (see page 1-3-12).
Misadjusted scanner center line. Readjust the scanner center line (see page 1-3-20).
Original placed incorrectly. Place the original correctly.