6-6 Epson TM-U950P Commands
ESC c 3 n
Select paper sensor(s) to output paper end signal
Hexadecimal code: 1B 63 33 n
Range:
n = 1-255
Selects the paper sensor(s) used to output paper end signal, using
n
as follows:
Bit Off/On Hex Decimal Function
0 Off 00 0 Journal near end sensor disabled.
On 01 1 Journal near end sensor enabled.
1 Off 00 0 Receipt near end sensor disabled.
On 02 2 Receipt near end sensor enabled.
2 Off 00 0 Journal sensor disabled.
On 04 4 Journal sensor enabled.
3 Off 00 0 Receipt sensor disabled.
On 08 8 Receipt sensor enabled.
4 Off 00 0 Slip insertion sensor disabled.
On 10 16 Slip insertion sensor enabled.
5 Off 00 0 Slip ejection sensor disabled.
On 20 32 Slip ejection sensor enabled.
6-7 - - - Undefined.
Notes:
- It is possible to select multiple sensors to output signals. Then if any sensor detects a
paper end, the paper end signal is output.
- This command is available only with a parallel interface and is ignored with a serial
interface.
Default:
n = 15