Save user preference dataset by the following procedure.
Step 1: Set “0: Unprotected” (default value) to User Preference Dataset Protection Function Selec-
tion (3020Hex-60Hex).
Step 2: When User Preference Dataset Registration (3020Hex-5FHex) is set to “1: Protected,” regis-
tration of the user preference dataset is started.
Step 3: To protect the user preference dataset, set “1: Protected (save prohibited)” to User Prefer-
ence Dataset Protection Function Selection (3020Hex-60Hex).
To set all user preference datasets to the factory defaults, initialize parameters by Data Initialization
(3008Hex-04Hex) “1: Initialize all parameters,” and then register the datasets by User Preference
Dataset Registration (3020Hex-5FHex).