40 H63 Frequency Lower
Limit Operation
Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
Mode selection when frequency ref-
erence is below lower limit
0: Operate at lower limit
1: Operate at frequency reference 0
Hz
0
√
--- Possible
41 H64 Low Frequency
during Protecting
Overload
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0: Depends on Frequency Lower
Limit (F16)
0.1 to 590.0
1.6
√
Hz Possible
44 H67 Auto Energy
Saving Operation
Condition Selec-
tion
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Enable only at constant speed
1: Enable in all modes
0
√
--- Possible
45 H68 1st Slip Compen-
sation Operating
Conditions Se-
lection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Enable during acceleration/decel-
eration, enable at base frequency or
higher
1: Disable during acceleration/decel-
eration, enable at base frequency or
higher
2: Enable during acceleration/decel-
eration, disable at base frequency or
higher
3: Disable during acceleration/decel-
eration, disable at base frequency or
higher
0 --- --- Possible
46 H69 Anti-regenerative
Control Function
Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Disable
2: Torque limit control with forced
stop after three times deceleration
time has passed
3: Main Circuit DC V
oltage control
with forced stop after three times de-
celeration time has passed
4: Torque limit control without forced
stop
5: Main Circuit DC Voltage control
without force-to-stop
0
√
--- Possible