EasyManua.ls Logo

Omron 3G3M1-A4110-ECT - Page 694

Omron 3G3M1-A4110-ECT
850 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Index
(hex)
Sub-
index
(hex)
Pa-
rame-
ter No.
Function name Monitor or data range
Default
data
Set-
ting
dur-
ing
RUN
Unit
PDO
map
0B A10 2nd DC Injection
Braking Level
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0 to 100 (HHD mode)
0 to 80 (HND/HD mode)
0 to 60 (ND mode)
Based on inverter rated current
0
% Possible
0C A11 2nd DC Injection
Braking Time
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00: Disable
0.01 to 30.00
0.00
s Possible
0D A12 2nd Starting Fre-
quency
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 60.0
0.5
Hz Possible
0E A13 2nd V/f Charac-
teristics Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Variable torque load
1: Constant torque load
1 --- --- Possible
0F A14 2nd Drive Control
Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: IM V/f control
1: IM Dynamic torque vector control
without speed sensor
3: IM V/f control with speed sensor
4: IM Dynamic torque vector control
with speed sensor
5: IM Vector control without speed
sensor
6: IM V
ector control with speed sen-
sor
0 --- --- Possible
10 A15 2nd Motor Pole
Number
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
2 to 128
4 --- Poles Possible
11 A16 2nd Motor Ca-
pacity
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.01 to 1,000
5.50 --- kW Possible
12 A17 2nd Motor Rated
Current
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00 to 500.0
21 --- A Possible
Appendices
A-148
M1 Series EtherCAT Type User’s Manual (I670)

Table of Contents

Related product manuals