EasyManua.ls Logo

Omron 3G3M1-A4110-ECT - Page 826

Omron 3G3M1-A4110-ECT
850 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Event name EtherCAT Communications Error Event code 28130000 hex
Meaning An error occurred in EtherCAT communications.
Source EtherCAT Master Function Mod-
ule
Source details Slave Detection tim-
ing
Continuously
Error attrib-
utes
Level Observation Recovery Error reset Log category System log
Effects User program Continues. Operation Not affected.
Indicators EtherCAT NET RUN EtherCAT NET ERR EtherCAT LINK/ACT
--- --- ---
System-de-
fined varia-
bles
Variable Data type Name
None None None
Cause and
correction
Assumed cause Correction Prevention
(1) An EtherCAT communica-
tions cable is disconnected, bro-
ken, short-circuited, or has a
contact failure in a daisy chain
configuration.
Connect the EtherCAT communi-
cations cable securely
. If the ca-
ble is broken, replace it.
Confirm that the EtherCA
T com-
munications cable is not broken
before use, and connect it se-
curely.
(2) In a ring topology configura-
tion, the ring disconnection sta-
tus occurred or was fixed.
Refer to 10-1-8 Method for Ring
Disconnection Maintenance and
Inspection on page
10-9 and per-
form inspection.
(3) Noise Take noise countermeasures so
that the noise does not affect the
EtherCA
T communications cable.
Take noise countermeasures so
that the noise does not affect the
EtherCAT communications cable.
Adjust the set value of
Communications Error Setting
(2200-00 hex).
(4) Failure in the EtherCAT phys-
ical layer of an inverter
If this event occurs again after
you performed all corrections
shown above, replace the inver-
ter.
None
Attached in-
formation
None
Precautions/
Remarks
None
Appendices
A-280
M1 Series EtherCAT Type User’s Manual (I670)

Table of Contents

Related product manuals