Section 2 Preparations
2-10
Preparations
E5ER-QT3DW-FLK (2-loop Control) E5ER-CT3DW-FLK (2-loop Control)
E5ER-PRTDF E5ER-PRQ43F-FLK
EDC
6
5
4
3
2
1
6
5
4
3
2
1
AB
D
3
6
5
4
2
1
D
+
+
-
-
SUB1
SUB2
Auxiliary outputs
(Transistor outputs)
E53-ART2
B(+)
A(
-
)
RS-485
+
+
-
-
+
-
3
6
5
4
2
1
OUT2
Voltage output
12 V 40 mA
OUT1
Voltage output
12 V 40 mA
or
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
C
E53-ARQC3
3
6
5
4
2
1
+
-
+
-
TCPTV
I
+
+
+
-
-
-
+
-
Input 1
Input 2
TC
(Thermocouple)
PT
(Resistance thermometer)
V
(Voltage)
I
(Current)
E5ER-AW-500
E
EV6
COM
EV5
EV4
EV3
3
6
5
4
2
1
B
E53-ARB4
Event inputs
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5ER-AW-500
100-240 VAC
24 VAC/DC
+
-
-
+
ED
C
6
5
4
3
2
1
6
5
4
3
2
1
B
A
B(+)
A(
-
)
RS-485
+
+
-
-
+
-
3
6
5
4
2
1
OUT2
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
OUT1
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
C
E53-ARCC3
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5ER-AW-500
D
3
6
5
4
2
1
D
+
+
-
-
SUB1
SUB2
Auxiliary outputs
(Transistor outputs)
E53-ART2
EV6
COM
EV5
EV4
EV3
3
6
5
4
2
1
B
E53-ARB4
3
6
5
4
2
1
+
-
+
-
TCPTV
I
+
+
+
-
-
-
+
-
Input 1
Input 2
TC
(Thermocouple)
PT
(Resistance thermometer)
V
(Voltage)
I
(Current)
E5ER-AW-500
E
Event inputs
100-240 VAC24 VAC/DC
+
-
-
+
EDC
6
5
4
3
2
1
6
5
4
3
2
1
AB
+
+
-
-
3
6
5
4
2
1
OUT4
Voltage output
12 V 40 mA
OUT3
Voltage output
12 V 40 mA or
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
D
3
6
5
4
2
1
Open
Closed
Relay output
250 VAC 1 A
B(+)
A(
-
)
RS-485
C
Input power supply depends
on the model.
100 to 240 VAC or 24 VAC/DC
(no polarity)
100-240 VAC24 VAC/DC
E5ER-PAF-500
E53-ARRR3
E53-ARQC
COM
SUB1
SUB2
COM
SUB3
SUB4
Auxiliary outputs
(Relay outputs)
3
6
5
4
2
1
B
E53-ARR4
C
W
O
Potentiometer
3
6
5
4
2
1
+
+
-
-
-
+
E
TC
(Thermocouple)
PT
(Resistance thermometer)
V
(Voltage)
I
(Current)
E5ER-PAF-500
+
-
-
+
OUT2
OUT1
+
-
EDC
6
5
4
3
2
1
6
5
4
3
2
1
BA
3
6
5
4
2
1
Open
Closed
Relay output
250 VAC 1 A
C
D
3
6
5
4
2
1
D
+
+
-
-
SUB1
SUB2
Auxiliary outputs
(Transistor outputs)
E53-ARRR
E53-ART2
C
W
O
Potentiometer
3
6
5
4
2
1
+
+
-
-
-
+
E
TC
(Thermocouple)
PT
(Resistance thermometer)
V
(Voltage)
I
(Current)
E5ER-PAF-500
EV6
COM
EV5
EV4
EV3
3
6
5
4
2
1
B
E53-ARB4
Event inputs
OUT2
OUT1
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5ER-PAF-500