EasyManua.ls Logo

Omron NE1A Series - Page 41

Omron NE1A Series
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
Wiring Section 3-2
Devices with Mechanical Contact Outputs
Examples: Emergency stop buttons and safety limit switches
These devices use both a safety input terminal and test output terminal. A
safety input terminal inputs the test output signal (pulse output) of the NE1A-
series Controller via a contact output device.
Devices with PNP Semiconductor Outputs (Current Sourcing)
Example: Light curtains
A PNP semiconductor output signal from this type of device is input to the
NE1A-series Controller’s safety input terminal.
INx
G1
Tx
V1
24 VDC
Minimum applicable load:
4 mA, 24 VAC
NE1A-series
Controller
4.5 mA typical
24 VDC
OSSDx
GND
INx
G1
Tx
V1
24 VDC
4.5 mA typical
NE1A-series
Controller
!WARNING
Serious injury may possibly occur due to loss of required safety functions. Use appropri-
ate components or devices according to the requirements given in the following table.
Controlling devices Requirements
Emergency stop switch Use approved devices with a direct opening mechanism compliant with IEC/
EN 60947-5-1.
Door interlocking switch or
limit switch
Use approved devices with a direct opening mechanism compliant with IEC/
EN 60947-5-1 and capable of switching micro-loads of 4 mA at 24 VDC.
Safety sensor Use approved devices compliant with the relevant product standards, regula-
tions, and rules in the country where they are used.

Table of Contents