Remote I/O Allocations Section 4-3
Data That Can Be Set and Example Arrangements
The following table shows the data that can be set.
Pre-Ver. 1.0 NE1A-series Controllers
NE1A-series Controllers with Unit Version 1.0 or Later
Sample 3: Transmitting Only Status Data as Standard Slave Inputs
Status C
Status A
Status Data
Connection
Standard Slave
Inputs
Input Data
Status A
Status B
Status C
Status D
Not set up
Data type Name/format Data size Setting method using
Network Configurator
Attribute
Status General Status Byte Set using checkbox. Non-
safety
Local Input Status Word Set using checkbox. Safety
Local Output Status Byte Set using checkbox. Safety
Test Output/Muting Lamp Status Byte Set using checkbox. Non-
safety
I/O tags BOOL I/O Tags Byte User registered. Safety
BYTE I/O Tags Byte User registered. Safety
WORD I/O Tags Word User registered. Safety
DWORD (Double Word) I/O Tags Double
word
User registered. Safety
Data type Name/format Data size Setting method using
Network Configurator
Attribute
Status General Status Byte Set using checkbox. Non-
safety
Local I/O Status
1 to N (See note 1.)
Byte Set using checkbox. Safety
Local Output Status Byte Set using checkbox. Safety
Test Output/Muting Lamp Status
1 to M (See note 1.)
Byte Set using checkbox. Non-
safety
Local I/O
monitor
Local Input Monitor
1 to N (See note 1.)
Byte Set using checkbox. Safety
Local Output Monitor Byte Set using checkbox. Safety
I/O tags BOOL I/O Tags Byte User registered. Safety
BYTE I/O Tags Byte User registered. Safety
WORD I/O Tags Word User registered. Safety
DWORD (Double Word) I/O Tags Double
word
User registered. Safety