587
Commands/Responses
Section 9-3
9-3-14 Bit memory table clear command (Sent from host to PT)
Command
[Format]
m
1B 43
[ESC]
C
(e3)
(b3)
(e4)
42
B (b1) (b2)
0D
(b4)
(e1) (e2)
(s1)
(s2)
[CR]
** ** ** ** **
** ** ** ** ** **
m : Check sum present/absent (1 BCD digit)
0 : Absent
1 : Present
b
1
to b
4
: First cleared bit memory table number (4 BCD digits)
0000 to 0999
e
1
to e
4
: Final cleared bit memory table number (4 BCD digits)
0000 to 0999
s
1
,s
2
: Check sum (2 hexadecimal digits)
When m is 0, omit this setting.
Reference:
The maximum number whichcan be specified for bit memory table depends onthe
setting for numbers of bit memory table entries (256/1000) made at the Support
Tool.
Response
Only if “Yes” is set for the “Response” memory switch, the response indicated be-
low is returned on normal completion.
[Format]
1B 43
[ESC] [CR]C
3030 30 0D42
B
30
0 0 s1 s2
s
1
,s
2
: Check sum (2 hexadecimal digits)
This is always added (fixed as “00H”).
[Function]
S Writes “OFF (0)” to all the bit memory tables within the specified range.

Table of Contents

Other manuals for Omron NT31