8 Checking Operation and Actual Operation
8 - 30
NX-series Safety Control Unit User’s Manual (Z930)
Use the following procedure to change the Safety CPU Unit to DEBUG mode (RUN) or DEBUG mode
(STOPPED).
With the Safety CPU Unit in DEBUG mode, perform one of the following operations.
•Select Debug
−
Start or Debug
−
Stop from the Controller Menu.
• Click the Start Debugging or Stop Debugging Button in the toolbar.
The Safety CPU Unit moves to DEBUG mode (RUN) or DEBUG mode (STOPPED).
8-6-2 Starting and Stopping the Safety Programs in DEBUG mode
WARNING
Before you start the system, perform user testing to make sure that all safety devices operate
correctly.
Serious injury may possibly occur due to loss of required safety functions.
Always confirm safety at the destination node before you transfer Unit configuration information,
parameters, settings, or other data from tools such as the Sysmac Studio.
The devices or machines may operate unexpectedly, regardless of the operating mode of the
Controller.
Starting and Stopping the Safety Programs

Table of Contents

Other manuals for Omron NX-SID800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NX-SID800 and is the answer not in the manual?

Omron NX-SID800 Specifications

General IconGeneral
ModelNX-SID800
Input Voltage24 VDC
Number of Input Points8
Number of Output Points0
Number of I/O Points8
Safety StandardIEC 61508 SIL3, ISO 13849-1 PLe
Connection MethodRemovable terminal block
Safety Category4

Related product manuals