Appendix
A - 36
NX-series Safety Control Unit Users Manual (Z930)
Precautions for Safe Use
Test the functionality every six months to detect welded contactor contacts.
The customer is responsible for attaining conformance of the entire system to standards.
To detect electrical and mechanical failures, use a combination of redundant semiconductor
output contacts and redundant mechanical output devices.
Refer to ISO 14119:2013 for additional measures to minimize the possibility of interlocking
devices associated with guards from being disabled.