EasyManua.ls Logo

Omron OMNUC G5 R88D-KT50F

Omron OMNUC G5 R88D-KT50F
632 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12-22
12-2 Parameter List
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
12
Appendix
Interface Monitor Setting Parameters
Pn number
Parameter
name
Description
Default
setting
Unit
Setting
range
Power
supply
OFF to
ON
400
Input Signal
Selection 1
Set the input signal 1 function and logic.
855309
0
0 to
00FFFFFFh
Yes
401
Input Signal
Selection 2
Set the input signal 2 function and logic.
848729
7
0 to
00FFFFFFh
Yes
402
Input Signal
Selection 3
Set the input signal 3 function and logic.
953985
0
0 to
00FFFFFFh
Yes
403
Input Signal
Selection 4
Set the input signal 4 function and logic. 394758
0 to
00FFFFFFh
Yes
404
Input Signal
Selection 5
Set the input signal 5 function and logic. 4108
0 to
00FFFFFFh
Yes
405
Input Signal
Selection 6
Set the input signal 6 function and logic. 197379
0 to
00FFFFFFh
Yes
406
Input Signal
Selection 7
Set the input signal 7 function and logic. 3847
0 to
00FFFFFFh
Yes
407
Input Signal
Selection 8
Set the input signal 8 function and logic. 263172
0 to
00FFFFFFh
Yes
408
Input Signal
Selection 9
Set the input signal 9 function and logic. 328965
0 to
00FFFFFFh
Yes
409
Input Signal
Selection 10
Set the input signal 10 function and logic. 3720
0 to
00FFFFFFh
Yes
410
Output Signal
Selection 1
Set the output signal 1 function allocation. 197379
0 to
00FFFFFFh
Yes
411
Output Signal
Selection 2
Set the output signal 2 function allocation. 131586
0 to
00FFFFFFh
Yes
412 Not used Do not change the set value. - −−
413
Output Signal
Selection 4
Set the output signal 4 function allocation. 328964
0 to
00FFFFFFh
Yes
Setting

Table of Contents

Related product manuals