12-32
12-2 Parameter List
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
12
Appendix
619
Encoder Phase-
Z Setting
Finely adjust the ON width of encoder
phase-Z signal output.
This is enabled when the phase-Z output
and phase-A output are not synchronized
(Pn011/Pn503
× Encoder resolution is not a
multiple of 4) due to the encoder dividing
ratio setting.
The set value of Pn619 and the ON width of
phase-Z output are related as follows:
Phase-Z output width [s] = 30/(Pn619
×
Motor speed [r/min])
0 Pulses
0 to
32,767
Yes
620
External Encoder
Phase-Z
Expansion Setting
Set the external encoder phase-Z output
width.
0 μs 0 to 400 Yes
621
Serial Absolute
External
Encoder Phase-
Z Setting
Set the phase-Z regeneration position when
the serial absolute external encoder is used.
0 Pulses 0 to 2
28
Yes
622
90
°
Phase
Difference Output
Type External
Encoder Phase-
AB Regeneration
Method Selection
Select the regeneration method of pulse
outputs A and B when a 90
°
phase difference
output type external encoder is used.
0 0 or 1 Yes
0 Without signal regeneration
1 With signal regeneration
623
Disturbance Torque
Compensation Gain
Set the compensation gain for the
disturbance torque.
0%
-100 to
100
624
Disturbance Observer
Filter Setting
Set the filter time constant for disturbance
torque compensation.
53
0.01
ms
10 to
2,500
627
Warning Latch
Hold Time
Selection
Select the warning latch time.
5 s 0 to 10 Yes
0 Latch time infinite
1
to
10
Latch time of 1 to 10 s
628 Not used Do not change the setting. −−
631
Realtime
Autotuning
Estimated
Speed
Selection
Set the load characteristics estimated speed
when realtime autotuning is enabled.
0 0 to 3
0
Finalize estimated results when load
estimation becomes stable.
1
Estimates every minute from the load
characteristic changes.
2
Estimates every second from the load
characteristic changes.
3
Estimates the optimum speed from the load
characteristic changes.
632
Realtime
Autotuning
Customization
Mode Setting
Set the Customization Mode detail for
realtime autotuning.
0
-32,768
to 32,767
Pn number
Parameter
name
Description
Default
setting
Unit
Setting
range
Power
supply
OFF to
ON
Setting