7 Appendix A
+
Inverter Model 3G3IV-
-
380 to 460 V
A4075A4055A4037A4022A4015A4007A4004
Overvoltage Motor coasts to a stop if converter output voltage exceeds
800 V.
Undervoltage Motor coasts to a stop if converter output voltage drops to
420 V or below (See Note 3).
Momentary power loss Immediately stop by 15 ms and above momentary power loss.
(Continuous system operation during power loss less than
2 sec is equipped as standard. See Note 2.) Setting made
before shipment.
Fin overheat Thermostat
Stall prevention Stall prevention at acceleration/deceleration and constant
speed operation
Protective functions Ground fault Provided by electronic circuit
Power charge indication Charge lamp stays ON until bus voltage drops below 50 V.
Environmental
Location Indoor (protected from corrosive gases and dust)
conditions
Ambient temperature +4° to 104°F(--10° to +40°C) (not frozen)
Storage temperature
(See Note 4)
--4° to 140°F(--20° to +60°C)
Humidity 90% RH (non-condensing)
Vibration 1Glessthan20Hz,upto0.2Gat20to50Hz
Note 1. Our standard 4-pole motor is used for max applicable motor output.
2. Allowable values for the applications not required overload.
3. For Models of 4.1 kVA or less, continuous system operation during power loss less than 1 sec, for
models with capacitor (option), less than 2 seconds.
4. Temperature during shipping (for short period).
Models B4110 to B4450
Inverter model 3G3IV-
-
380 to 460 V
B4110 B4150 B4185 B4220 B4300 B4370 B4450
Max. applicable motor output Hp (kW) (See Note 1) 15
(11)
20
(15)
25
(18.5)
30
(22)
40
(30)
50
(37)
60
(45)
Output characteristics Inverter capacity kVA 20.6 27.4 34 41 54 68 82
Rated output current A 24 32 40 48 64 80 96
Max. continuous output
current (See Note 2) A
27 36 45 54 72 90 108
Max. output voltage 3-phase, 200/208/220/230 V (Proportional to input voltage)
Rated output frequency 50, 60, 72, 90, 120, 180 Hz (up to 400 Hz available)
Power Supply Rated input voltage and
frequency
3-Phase 200/208/220 V, 50 Hz 200/208/220/230 V, 60 Hz
Allowable voltage fluctuation ±10%
Allowable frequency
fluctuation
±5%
Control characteristics Control method Sine wave PWM
Frequency control range 0.1 to 400 Hz
Frequency accuracy Digital command: 0.01%, +14° to 104°F, -- 10 ° to 40°C
Analog command: 0.1%, 77°
±
18°F, 25°
±
10°C
Frequency resolution Digital operator reference: 0.1 Hz
Analog reference: 0.06 Hz/60 Hz