15
Control Circuit (Terminals Factory Preset)
Control Circuit Terminal Functions
Classification Terminal Signal name Function Signal level
Sequence
Input Signal
1 Forward run/stop signal Forward run when “closed”,
stop when “open”.
Photo-coupler
insulation input
2 Reverse run/stop signal Reverse run when “closed”,
stop when “open”.
24 VDC 8 mA
3 Fault reset signal Reset when “closed”.
4 External fault External fault when “closed”.
5 Multi-step speed ref. 1
Multi-step
speed ref. 1
Multifunction
contact input:
6 Sequence control input
common terminal
effective
two signals
available to
select
1
Analog Input
Signal
10 Power supply terminal
for frequency setting
Speed ref. power supply 12 V (Allowable
current 20 mA max.)
8
Frequency ref.
0 to 10 V/Max. output
frequency
0 to 10 V (20 kΩ)
9 4 to 20 mA/Max. output
frequency
4 to 20 mA (250 Ω)
11 Common terminal for
control circuit
0 V –––
Sequence
13 During running “L” level at run
Multifunction
Photo-coupler output
Output Signal
14 Frequency agreed
signal
“L” level at set
frequency =
output
frequency
contact input:
two signals
available to
select
2
48 V, 50 mA max.
7 Photo-coupler output
common
–––
FLT-A
Fault signal contact “Closed” between A and C at
Contact capacity
FLT-B
output fault
“
p
”
250 VAC: 1 A max.
FLT-C Fault signal contact
output common
pen
etween
an
at
fault
30
: 1
max.
Analog Output
Signal
12 Frequency meter
0 to 10 V/Max. output
frequency.
0 to 11 V max.
2 mA or less
11 Common
Possible to select current
meter output.
3
Note 1. For details refer to
2-8-14 Multifunction Contact Input Function
Selection
.
2. For details refer to
2-8-15 Multifunction Output Function
.
3. For details refer to
2-8-9 Multifunction Analog Output Monitor
.
Control Circuit Terminal Arrangement
8 9 10 11 12 13 14
FLT FLT FLT 1 2 3 4 5 6 7
A B C
Wiring Section 1-4