EasyManua.ls Logo

Omron SYSMAC CP2E-E D Series

Omron SYSMAC CP2E-E D Series
578 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 Pulse Outputs
12-70
CP2E CPU Unit Software User’s Manual(W614)
Stopping a Pulse Output
Operation
Example
application
Frequency changes Description
Procedure
Instruction Settings
Stop pulse
output
(Number of
pulses set-
ting is not
preserved.)
Immediate
stop
Stops the pulse output immedi-
ately and clears the number of
output pulses setting.
PULS
ACC or SPED
(Independent)
INI
Stop pulse
output
PLS2
INI
Stop pulse
output
(Number of
pulses set-
ting is not
preserved.)
Immediate
stop
Stops the pulse output immedi-
ately and clears the number of
output pulses setting.
PULS
SPED
(Independent)
SPED
(Independent)
Port
Indepen-
dent
Target fre-
quency = 0
Stop sloped
pulse out-
put
smoothly.
(Number of
pulses set-
ting is not
preserved.)
Decelerate
to a stop
Decelerates the pulse output
to a stop.
If ACC started the operation,
the original acceleration/decel-
eration rate will remain in
effect.
If SPED started the operation,
the acceleration/deceleration
rate will be invalid and the
pulse output will stop immedi-
ately.
PULS
ACC or SPED
(Independent)
ACC
(Independent)
Port
Indepen-
dent
Target fre-
quency = 0
PLS2
ACC
(Independent)
Pulse frequency
Present
frequency
Execution
of SPED
Execution
of INI
Time
Pulse frequency
Present
frequency
Execution
of SPED
Execution
of SPED
Time
Pulse frequency
Present
frequency
Target
frequency=0
Original acceleration/
deceleration rate
Execution of ACC
Time

Table of Contents

Related product manuals