15 Ethernet
15-60
CP2E CPU Unit Software User’s Manual(W614)
A47 0 FINS/TCP Con-
nection Flag 1
ON Turned ON by the Unit when a connection is
established.
Read only
OFF Turned OFF by the Unit when the connection
is terminated.
1 FINS/TCP Con-
nection Flag 2
ON Turned ON by the Unit when a connection is
established.
OFF Turned OFF by the Unit when the connection
is terminated.
2 FINS/TCP Con-
nection Flag 3
ON Turned ON by the Unit when a connection is
established.
OFF Turned OFF by the Unit when the connection
is terminated.
A500 11 Ethernet Commu-
nication Error
Clear Flag
ON If this flag is set to ON, Ethernet communica-
tion error flag (A46.15) will be cleared (OFF).
Read/write
OFF OFF after Ethernet communication error has
been cleared.
Address Bit(s) Name Status Unit operation Access