CIDRW System
User’s Manual
SECTION 5
When SECS is Used
SECTION 5
Troubleshooting
When the CIDRW Controller fails to respond to messages sent to it
There is a mistake in the CIDRW Controller or Amplifier Unit settings.
After taking the appropriate corrective action, restart the CIDRW Controller and Amplifier Unit.
When an error unrelated to message transmission and responses occurs
There is a mistake in the settings of the CIDRW Controller and Amplifier Unit.
After taking the appropriate corrective action, restart the CIDRW Controller and Amplifier Unit.
POWER OPERATING ALARMS BUSY ERROR Main check points
Mode switch setting (Is the setting 0?)
Cable wiring between the CIDRW Controller
and host device
Communications conditions for communication
between the CIDRW Controller and host
device (baud rate, character composition, etc.)
Cable wiring between the CIDRW Controller
and host device
Node numbers of the Amplifier Units (The
same number is set for more than one unit.)
POWER OPERATING ALARMS BUSY ERROR Main check points
Mode switch setting (Is the setting 0?)
Amplifier Unit baud rate settings
Node numbers of the Amplifier Units (The
same number is set for more than one unit.)
Connection and wiring of cable between
CIDRW Controller and Amplifier Unit
Amplifier Unit error (hardware error)
Routing of each cable (influence of back-
ground noise)