Operation
68
7.3 Web Client
To access the Web Client on your computer first the Ethernet interface needs to be set up to have a proper
communication between your computer and the Compute Box. It is recommended to use Auto mode (for
further details see section Ethernet Interface setup).
Then do the following steps:
• Connect the Compute Box to your computer with the supplied UTP cable.
• Power the Compute Box with the supplied power supply
• Wait one minute for the Compute Box LED to turn from blue to green.
• Open a web browser on your computer and type in the IP address of the Compute Box (factory
default is 192.168.1.1).
The Sign-in page opens:
The factory default administrator login is:
Username: admin
Password: OnRobot