In case, more than one Compute Box is used within the same network, for identification
purpose any user specific name can be entered to the Display name.
EtherNet/IP scanner settings:
NOTE:
This is a special option of the EtherNet/IP connection for some robots.
In case when the robot is the Adapter and the Compute Box needs to be the Scanner the
following addition information is required for the communication:
IP address to connect to - the robot IP address
Origin-to-target instance id - refer to the robot's EtherNet/IP manual (Scanner mode)
Target-to-origin instance id - refer to the robot's EtherNet/IP manual (Scanner mode)
Configuration instance id - refer to the robot's EtherNet/IP manual (Scanner mode)
Requested packet interval (ms) - RPI value in ms (minimum 4)
Check the checkbox and the Compute Box will try to automatically connect to the robot (via
the given IP address).
7.1.5. Web Client: Update Menu
This page can be used to update the software on the Compute Box and the
firmware on the
devices.
ADDITIONAL SOFTWARE OPTIONS