Opticon
OPR 3001
Specifications Manual
10
6. Optical Specifications
6.1. Laser Scan Specifications
Parameter Specification Unit
Light-emitting element Red laser diode
Emission wavelength 650 ±10 (25° C) nm
Light output 1.0 or less mW
Scanning method Bi-directional scanning
Scanning speed 100 ±20 scans/s
Scan angle: 54 ±5 ° Scan angle
Read angle: 44 (Min) °
Auto-trigger IR detection area 40 mm
Notes:
Refer to chapter 15, “Trigger and Read Options,” to read about the scan modes.
Refer to chapter 7, “Technical Specifications,” to read about scanning performance.
6.1.1.
Tilt of Laser Scan Line
Laser scanning tilt is the vertical difference between both ends of a laser scan
line. Measure it in the middle of the laser scan line.
Maximum tilt between both ends of laser scan line: Less than 1.2° upward tilt from
the scan origin.
Maximum of 3.1 mm when measured at a point 150 mm away from the scan
origin. (The skew angle of this measurement was zero degrees.)

Table of Contents