37
13.4. Dust and Drip Proof
IEC IP54
Dust Prevention
Level Details
5
Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with
the satisfactory operation of the equipment; complete protection against contact.
Water Prevention
Level Details
4 Water splashing against the enclosure from any direction shall have no harmful effect.
13.5. Cable Strength
Affixed the scanner to an immovable object and pulled it using a force of 49N (5.0
kgf) for 1 minute. Observed no abnormality in either structure or performance.
13.6. Cable Bending Test
As shown below, added a load of 4.9N (500 g) to a cable then bent it at an angle
of 90 degrees to both right and left. Count 1 time by bending to either side;
repeated this 3 million times on RS-232C and Wedge cables and repeated 1
million times on USB cable. Observed no abnormality in either structure or
performance. Note: Cable bending resistance is not warrantable.
Figure 26: Cable bend strength