EasyManua.ls Logo

Opticon OPR 3001 - Dust and Drip Proof; Cable Strength; Cable Bending Test; Figure 26: Cable Bend Strength

Opticon OPR 3001
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Opticon
OPR 3001
Specifications Manual
37
13.4. Dust and Drip Proof
IEC IP54
Dust Prevention
Level Details
5
Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with
the satisfactory operation of the equipment; complete protection against contact.
Water Prevention
Level Details
4 Water splashing against the enclosure from any direction shall have no harmful effect.
13.5. Cable Strength
Affixed the scanner to an immovable object and pulled it using a force of 49N (5.0
kgf) for 1 minute. Observed no abnormality in either structure or performance.
13.6. Cable Bending Test
As shown below, added a load of 4.9N (500 g) to a cable then bent it at an angle
of 90 degrees to both right and left. Count 1 time by bending to either side;
repeated this 3 million times on RS-232C and Wedge cables and repeated 1
million times on USB cable. Observed no abnormality in either structure or
performance. Note: Cable bending resistance is not warrantable.
Figure 26: Cable bend strength

Table of Contents