Supported Components and Capabilities
18 Oracle Database Appliance Owner's Guide • March 2017
Component Oracle Database Appliance
(Version 1)
Oracle Database Appliance
X3-2
Oracle Database Appliance
X4-2
Oracle Database Appliance
X5-2
to the data center or public
network is required. See
“Optional Component
Installation” on page 58.
Network
management
(NET MGT)
port
One 10/100Base-T network
interface port with RJ-45
connector dedicated to the
service processor (SP) on
the back panel of each server
node.
One 10/100Base-T network
interface port with RJ-45
connector dedicated to the
service processor (SP) on
the back panel of each server
node.
One 10/100Base-T network
interface port with RJ-45
connector dedicated to the
service processor (SP) on
the back panel of each server
node.
One 10/100/1000Base-T
network interface port with
RJ-45 connector dedicated to
the service processor (SP) on
the back panel of each server
node.
Serial
management
(SER MGT)
port
One RS-232 RJ-45 serial
port on the back panel of
each server node.
One RS-232 RJ-45 serial
port on the back panel of
each server node.
One RS-232 RJ-45 serial
port on the back panel of
each server node.
One RS-232 RJ-45 serial
port on the back panel of
each server node.
VGA port One high-density HD-15
video port on the back panel
of each server node.
One high-density HD-15
video port on the back panel
of each server node.
One high-density HD-15
video port on the back panel
of each server node.
One high-density HD-15
video port on the back panel
of each server node.
Service
Processor
(SP)
Each server node has a
service processor with the
following features:
Includes the Baseboard
Management Controller
(BMC), which supports
the industry-standard
Intelligent Platform
Management Interface
(IPMI) feature set.
Supports remote KVMS
over IP.
Supports Ethernet
access to SP through a
dedicated 10/100Base-
T management port and
optionally through one
of the host GbE ports
(sideband management)
Each server node has a
service processor with the
following features:
Includes the Baseboard
Management Controller
(BMC), which supports
the industry-standard
Intelligent Platform
Management Interface
(IPMI) feature set.
Supports remote KVMS
over IP.
Supports Ethernet
access to SP through a
dedicated 10/100Base-
T management port and
optionally through one
of the host GbE ports
(sideband management).
Each server node has a
service processor with the
following features:
Includes the Baseboard
Management Controller
(BMC), which supports
the industry-standard
Intelligent Platform
Management Interface
(IPMI) feature set.
Supports remote KVMS
over IP.
Supports Ethernet
access to SP through a
dedicated 10/100Base-
T management port and
optionally through one
of the host GbE ports
(sideband management).
Each server node has a
service processor with the
following features:
Includes the Baseboard
Management Controller
(BMC), which supports
the industry-standard
Intelligent Platform
Management Interface
(IPMI) feature set.
Supports remote KVMS
over IP.
Supports Ethernet
access to SP
through a dedicated
10/100/1000Base-T
management port and
optionally through one
of the host GbE ports
(sideband management).
Power
supplies
Two hot-pluggable power
supplies per chassis.
Two hot-pluggable power
supplies per server node and
per storage shelf.
Two hot-pluggable power
supplies per server node and
per storage shelf.
Two hot-pluggable power
supplies per server node and
per storage shelf.
Cooling fans Two redundant hot-
pluggable fan modules per
server node.
Four 40-mm, hot-pluggable
fan modules per server node
for chassis cooling. Each
fan module contains two
counter-rotating fan pairs
(four rotors total).
Each power supply (server
node and storage shelf) has
its own cooling fans.
Four 40-mm, hot-pluggable
fan modules per server node
for chassis cooling. Each
fan module contains two
counter-rotating fan pairs
(four rotors total).
Each power supply (server
node and storage shelf) has
its own cooling fans.
Four 40-mm, hot-pluggable
fan modules per server node
for chassis cooling. Each
fan module contains two
counter-rotating fan pairs
(four rotors total).
Each power supply (server
node and storage shelf) has
its own cooling fans.