EasyManuals Logo

ORGA L85EX User Manual

ORGA L85EX
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Version 2.1 27
TROUBLESHOOTING
4 TROUBLESHOOTING
4.1 Failure of the light fixture
The table below gives the possible problems and its solution.
If the problem is not listed below, contact Orga BV.
WARNING
Only an electrical engineer is allowed to do maintenance on the electrical
system.
Problem Possible cause Solution
The light is off Failure at the power supply. Make sure that the power sup-
ply to the control panel is ener-
gized.
Check the alarm messages on
the control panel. See the
instructions in the control panel.
Bad connection of the wiring Check the internal connections
Refer to 4.2.
Power failure Check the power supply cable
on both sides. Refer to 4.2.2.
Defective LED(s) Contact Orga.
Wire breakage Check the internal connections
Refer to 4.2.
Unknown If you cannot solve the problem,
contact Orga.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ORGA L85EX and is the answer not in the manual?

ORGA L85EX Specifications

General IconGeneral
BrandORGA
ModelL85EX
CategoryLight Fixture
LanguageEnglish