Pag. 60OM4054_GB
4. EMERGENCY CONDITIONS
4.1. DEFINITION
Intervention under emergency conditions is the recovery of the personnel blocked on
the cage in aerial position, for a sudden illness, or for a breakdown.
e reasons for a recovery can be of two kinds: illness of the people driving the cage or
machine damage (due to a lack of the engine power, settling of the pumps, battery or
exible pipes damage, electric failures).
In this last case, the persons on the platform may have become unable to move but can
use the emergency devices placed near them.
Any other emergency situation (fi re, earthquake, etc.) is not considered, as the machine
is not designed for fi re- ghting and for rescue service.
Time for the recovery operations is not necessarily short.
Information
To perform some emergency maneuvers, may be necessary the help of
more people.
4.2. EMERGENCY CONDITIONS
The platform is provided with safety devices protecting the personnel during the nor-
mal work and also allowing the recovery in case of a possible breakdown.
Main emergency devices are: dual power source, dual control stations, emergency
stop push buttons, intercom communication system, supplementary hand pump, direct
control of electro-distributor valves.
1. Rules to follow during the emergency operations
Platform is provided with several devices for aerial cage recovery. Therefore, it is
recommended to follow these directions, avoiding operators descent by cables, along
the boom, etc. IT’S VERY DANGEORUS!!!
Danger
In case the operator on the aerial cage is seized by a sudden illness,
before touching the platform, be sure that boom or cage are not in
contact with live electric lines.
DON’T TOUCH THE PLATFORM, ALSO FOR PERSONS AT
GROUND THERE IS A SERIOUS ELECTROCUTION HAZARD