Tel. 0039 030 6857073 - Fax 0039 030657079 info@palazzani.it - www.palazzani.it
Pag. 69OM4054_GB
If the travelling doesn’t work, verify that:
the selector key is in the center
one or more stabilizers are on the ground
are there oil leaking or some damaged components
there are no system alarms on the display.
If the boom movements doesn’t work, verify that:
the control panel on the ground is enabled (key pictures 3.1 position 2)
the red lamp on the control panel is not switched on
the hydraulic oil level is good
all the stabilizers pin are correctly placed
the chassis angle is into the safety value (2°)
all the stabilizers are on the ground with a good pressure
there are no system alarms on the display.
In case of vibrations or irregular movements, verify that:
telescopic boom sections are greased
the chains of the booms are regularly tensed and hydraulic oil level is regular
after a repair intervention, the presence of air is possible in the hydraulic system - in
this case, it is recommended to make two complete movements sequences, to end
stroke, starting from stabilizing legs
A lot of checks can be made from the touch screen display on boards.
For more informations about that, check the manual part regarding the display.