6-3. PC EVR Software operation
< Function of PC EVR Software >
The following confirmation and the setup can be performed by PC EVR software (VVS0069)
Setting of destination
Write UID data
Setting of data and Time of internal clock
Factory initialize
Software Version Display (XP section)
Save and write EEPROM (XP section) Please refer to item “7. Save and write EEPROM data(page INF-29)
VIDEO Level adjustment Please refer to item “2. Adjustment procedure” on Section 3 (Electrical Adjustment)
6-3-1. Setting of destination
NOTE: For AG-HMC151E model, “Setting of destination” is not required.
1. Select “Editing the ARM memory (E
)” in “Edit (M)” menu.
2. Set it as follows and click “Execute(E
)” button on ARM Edit Memory screen.
ADRS (Address)
0052
CMD (Command)
Write 1byte
DAD (Device)
RAM
[ADRS (Address)]: “0052”
[CMD (Command)]: Write 1byte
[DAD (Device)]: RAM
[Data (Input/Output)]
Destination P AN EN ER MC
Setting value 01 0C 81 83 03